Manufacturers
  • Advanced Electric Systems LLC

HTQF 3L (100 A- 300 A, 400 V)

/
Displaying 1 to 4 (of 4 products)
  • Active power filter HTQF 3L-0.4/100A  (100 A, 400 V)

    Active power filter HTQF 3L-0.4/100A (100 A, 400 V)

    Active power filter HTQF 3L:Rate voltage:      400 V;Rate current:      100 AIncoterms:        FOB Qingdao;payment:           30% T/T befor production;                          70% T/T befor shipment;Package:             wooden case;Delivery time:     35 days.HTQF type active power filter Product details brochure >>More functions, more modes  Fractional compensation of harmonics can be set according to actual needs;  Harmonic reactive compensation is equipped with 4 working modes, namely, “filter priority”, “reactive power priority”, “harmonic filter only”, “reactive power compensation only”, which can satisfy the compensation need for various power distribution systems;  Balance compensation function can balance the load current among phases; RS485 interface, standard MODBUS RTU communication protocol, and computer remote monitoring function.More stable, more reliable  Optical fiber drive can guarantee high security, reliability and anti-jamming capability; Multi-protection, strict thermal design can ensure the secure and reliable operation of the system; Advanced control algorithms can offer stable operation for various complex environments, and it can also conduct parallel operation with capacitor compensating box; Digital control, LCD working platform Chinese or English; Self-diagnosis functionRecord of historical events functionHigher power density, easier installation and maintenance Modular design of converter can guarantee high power density, and easy installation and maintenance; Output capacity is high. Single-unit output capacity can reach up to 600A; It can conduct multi-machine parallel operation to satisfy various needs for compensation capacity. Automatic current limiting will be conducted once output capacity is fully loaded,  so it is free of the trouble in overloading;  Detection methods of source current and load current are optional for the convenience of field installation.    HTQF/3L 4L model table HTQF 3L 4L-0.4/□□□A      three phase three line power filter model 100A 150A 200A 250A 300A 400A 500A 600A Wiring method Three phase three line Wiring method Three phase four line   Rated voltage V 400    -20/+15% Rated frequency Hz 50/60 Rated compensation current A 100 150 200 250 300 400 500 600 Rated compensation capacity  kvar 66 100 133 165 200 266 330 400 weight kG 330 370 390 460 520 640 740 880 Cabinet type MNS or GGD or other installation landing width       mm 600 800 1000 depth     mm 800 1000 height      mm 2200 Current detection method load current detection or source current detection, optional color REL7035 (can be customized) Protection level IP3X(can be customized) Line incoming Up or down

  • Active power filter HTQF 3L-0.4/150A  (150 A, 400 V)

    Active power filter HTQF 3L-0.4/150A (150 A, 400 V)

    Active power filter HTQF 3L:Rate voltage:      400 V;Rate current:      150 AIncoterms:        FOB Qingdao;payment:           30% T/T befor production;                          70% T/T befor shipment;Package:             wooden case;Delivery time:     35 days.HTQF type active power filter Product details brochure >>More functions, more modes  Fractional compensation of harmonics can be set according to actual needs;  Harmonic reactive compensation is equipped with 4 working modes, namely, “filter priority”, “reactive power priority”, “harmonic filter only”, “reactive power compensation only”, which can satisfy the compensation need for various power distribution systems;  Balance compensation function can balance the load current among phases; RS485 interface, standard MODBUS RTU communication protocol, and computer remote monitoring function.More stable, more reliable  Optical fiber drive can guarantee high security, reliability and anti-jamming capability; Multi-protection, strict thermal design can ensure the secure and reliable operation of the system; Advanced control algorithms can offer stable operation for various complex environments, and it can also conduct parallel operation with capacitor compensating box; Digital control, LCD working platform Chinese or English; Self-diagnosis functionRecord of historical events functionHigher power density, easier installation and maintenance Modular design of converter can guarantee high power density, and easy installation and maintenance; Output capacity is high. Single-unit output capacity can reach up to 600A; It can conduct multi-machine parallel operation to satisfy various needs for compensation capacity. Automatic current limiting will be conducted once output capacity is fully loaded,  so it is free of the trouble in overloading;  Detection methods of source current and load current are optional for the convenience of field installation.    HTQF/3L 4L model table HTQF 3L 4L-0.4/□□□A      three phase three line power filter model 100A 150A 200A 250A 300A 400A 500A 600A Wiring method Three phase three line Wiring method Three phase four line   Rated voltage V 400    -20/+15% Rated frequency Hz 50/60 Rated compensation current A 100 150 200 250 300 400 500 600 Rated compensation capacity  kvar 66 100 133 165 200 266 330 400 weight kG 330 370 390 460 520 640 740 880 Cabinet type MNS or GGD or other installation landing width       mm 600 800 1000 depth     mm 800 1000 height      mm 2200 Current detection method load current detection or source current detection, optional color REL7035 (can be customized) Protection level IP3X(can be customized) Line incoming Up or down

  • Active power filter HTQF 3L-0.4/200A  (200 A, 400 V)

    Active power filter HTQF 3L-0.4/200A (200 A, 400 V)

    Active power filter HTQF 3L:Rate voltage:      400 V;Rate current:      200 AIncoterms:        FOB Qingdao;payment:           30% T/T befor production;                          70% T/T befor shipment;Package:             wooden case;Delivery time:     35 days.HTQF type active power filter Product details brochure >>More functions, more modes  Fractional compensation of harmonics can be set according to actual needs;  Harmonic reactive compensation is equipped with 4 working modes, namely, “filter priority”, “reactive power priority”, “harmonic filter only”, “reactive power compensation only”, which can satisfy the compensation need for various power distribution systems;  Balance compensation function can balance the load current among phases; RS485 interface, standard MODBUS RTU communication protocol, and computer remote monitoring function.More stable, more reliable  Optical fiber drive can guarantee high security, reliability and anti-jamming capability; Multi-protection, strict thermal design can ensure the secure and reliable operation of the system; Advanced control algorithms can offer stable operation for various complex environments, and it can also conduct parallel operation with capacitor compensating box; Digital control, LCD working platform Chinese or English; Self-diagnosis functionRecord of historical events functionHigher power density, easier installation and maintenance Modular design of converter can guarantee high power density, and easy installation and maintenance; Output capacity is high. Single-unit output capacity can reach up to 600A; It can conduct multi-machine parallel operation to satisfy various needs for compensation capacity. Automatic current limiting will be conducted once output capacity is fully loaded,  so it is free of the trouble in overloading;  Detection methods of source current and load current are optional for the convenience of field installation.    HTQF/3L 4L model table HTQF 3L 4L-0.4/□□□A      three phase three line power filter model 100A 150A 200A 250A 300A 400A 500A 600A Wiring method Three phase three line Wiring method Three phase four line   Rated voltage V 400    -20/+15% Rated frequency Hz 50/60 Rated compensation current A 100 150 200 250 300 400 500 600 Rated compensation capacity  kvar 66 100 133 165 200 266 330 400 weight kG 330 370 390 460 520 640 740 880 Cabinet type MNS or GGD or other installation landing width       mm 600 800 1000 depth     mm 800 1000 height      mm 2200 Current detection method load current detection or source current detection, optional color REL7035 (can be customized) Protection level IP3X(can be customized) Line incoming Up or down

  • Active power filter HTQF 3L-0.4/300A  (300 A, 400 V)

    Active power filter HTQF 3L-0.4/300A (300 A, 400 V)

    Active power filter HTQF 3L:Rate voltage:      400 V;Rate current:      300 AIncoterms:        FOB Qingdao;payment:           30% T/T befor production;                          70% T/T befor shipment;Package:             wooden case;Delivery time:     35 days.HTQF type active power filter Product details brochure >>More functions, more modes  Fractional compensation of harmonics can be set according to actual needs;  Harmonic reactive compensation is equipped with 4 working modes, namely, “filter priority”, “reactive power priority”, “harmonic filter only”, “reactive power compensation only”, which can satisfy the compensation need for various power distribution systems;  Balance compensation function can balance the load current among phases; RS485 interface, standard MODBUS RTU communication protocol, and computer remote monitoring function.More stable, more reliable  Optical fiber drive can guarantee high security, reliability and anti-jamming capability; Multi-protection, strict thermal design can ensure the secure and reliable operation of the system; Advanced control algorithms can offer stable operation for various complex environments, and it can also conduct parallel operation with capacitor compensating box; Digital control, LCD working platform Chinese or English; Self-diagnosis functionRecord of historical events functionHigher power density, easier installation and maintenance Modular design of converter can guarantee high power density, and easy installation and maintenance; Output capacity is high. Single-unit output capacity can reach up to 600A; It can conduct multi-machine parallel operation to satisfy various needs for compensation capacity. Automatic current limiting will be conducted once output capacity is fully loaded,  so it is free of the trouble in overloading;  Detection methods of source current and load current are optional for the convenience of field installation.    HTQF/3L 4L model table HTQF 3L 4L-0.4/□□□A      three phase three line power filter model 100A 150A 200A 250A 300A 400A 500A 600A Wiring method Three phase three line Wiring method Three phase four line   Rated voltage V 400    -20/+15% Rated frequency Hz 50/60 Rated compensation current A 100 150 200 250 300 400 500 600 Rated compensation capacity  kvar 66 100 133 165 200 266 330 400 weight kG 330 370 390 460 520 640 740 880 Cabinet type MNS or GGD or other installation landing width       mm 600 800 1000 depth     mm 800 1000 height      mm 2200 Current detection method load current detection or source current detection, optional color REL7035 (can be customized) Protection level IP3X(can be customized) Line incoming Up or down

/
Displaying 1 to 4 (of 4 products)