  • Circuit Breaker CAM1-125L, 100 A

    Circuit Breaker CAM1-125L, 100 A

    Circuit breaker CAM1-125L, 100A Rated Voltage: 400 V;Rated Current: 100 ASize: 150 mm x 92 mm x 72 mm (LxWxH)Weight (g): 1257 Payment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAM1 series moulded case circuit breaker (named as MCCB in the following) is a new type breaker which is applied with rated insulating voltage 800V (500V for CAM1-63), rated working voltage 690V for CAM1-63) andused for infrequent exchange and startup in AC(60)Hz condition. The MCCB is of protecting functioin in overloading,short-circuit, and under voltage situation to protect circuit system and power device from damage.The MCCB can be devided into L;M;H types according to their rated limit short-circuit breaking capacity.The MCCB is advantageous for its compact body, high breaking capacity (some even on flying arc), short arc-castig and superior aseismatic function.The MCCB has function of insulation with its mark (normal open contact).The product complies with IEC60947-2, GB14048.2.

  • Circuit Breaker CAM1-125L, 125 A

    Circuit Breaker CAM1-125L, 125 A

    Circuit breaker CAM1-125L, 125A Rated Voltage: 400 V;Rated Current: 125 ASize: 150 mm x 92 mm x 72 mm (LxWxH)Weight (g): 1257 Payment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAM1 series moulded case circuit breaker (named as MCCB in the following) is a new type breaker which is applied with rated insulating voltage 800V (500V for CAM1-63), rated working voltage 690V for CAM1-63) andused for infrequent exchange and startup in AC(60)Hz condition. The MCCB is of protecting functioin in overloading,short-circuit, and under voltage situation to protect circuit system and power device from damage.The MCCB can be devided into L;M;H types according to their rated limit short-circuit breaking capacity.The MCCB is advantageous for its compact body, high breaking capacity (some even on flying arc), short arc-castig and superior aseismatic function.The MCCB has function of insulation with its mark (normal open contact).The product complies with IEC60947-2, GB14048.2.

  • Circuit Breaker CAM1-125L, 80 A

    Circuit Breaker CAM1-125L, 80 A

    Circuit breaker CAM1-125L, 80A Rated Voltage: 400 V;Rated Current: 80 ASize: 150 mm x 92 mm x 72 mm (LxWxH)Weight (g): 1257Payment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAM1 series moulded case circuit breaker (named as MCCB in the following) is a new type breaker which is applied with rated insulating voltage 800V (500V for CAM1-63), rated working voltage 690V for CAM1-63) andused for infrequent exchange and startup in AC(60)Hz condition. The MCCB is of protecting functioin in overloading,short-circuit, and under voltage situation to protect circuit system and power device from damage.The MCCB can be devided into L;M;H types according to their rated limit short-circuit breaking capacity.The MCCB is advantageous for its compact body, high breaking capacity (some even on flying arc), short arc-castig and superior aseismatic function.The MCCB has function of insulation with its mark (normal open contact).The product complies with IEC60947-2, GB14048.2.

  • Circuit Breaker CAM1-63L, 25 A

    Circuit Breaker CAM1-63L, 25 A

    Circuit breaker CAM1-63L, 25A Rated Voltage: 400 V;Rated Current: 25 ASize: 135 mm x 78 mm x 73.5 mm (LxWxH)Weight (g): 735Payment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAM1 series moulded case circuit breaker (named as MCCB in the following) is a new type breaker which is applied with rated insulating voltage 800V (500V for CAM1-63), rated working voltage 690V for CAM1-63) andused for infrequent exchange and startup in AC(60)Hz condition. The MCCB is of protecting functioin in overloading,short-circuit, and under voltage situation to protect circuit system and power device from damage.The MCCB can be devided into L;M;H types according to their rated limit short-circuit breaking capacity.The MCCB is advantageous for its compact body, high breaking capacity (some even on flying arc), short arc-castig and superior aseismatic function.The MCCB has function of insulation with its mark (normal open contact).The product complies with IEC60947-2, GB14048.2.

  • Circuit Breaker CAM1-63L, 40 A

    Circuit Breaker CAM1-63L, 40 A

    Circuit breaker CAM1-63L, 40A Rated Voltage: 400 V;Rated Current: 40 ASize: 135 mm x 78 mm x 73.5 mm (LxWxH)Weight (g): 735Payment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAM1 series moulded case circuit breaker (named as MCCB in the following) is a new type breaker which is applied with rated insulating voltage 800V (500V for CAM1-63), rated working voltage 690V for CAM1-63) andused for infrequent exchange and startup in AC(60)Hz condition. The MCCB is of protecting functioin in overloading,short-circuit, and under voltage situation to protect circuit system and power device from damage.The MCCB can be devided into L;M;H types according to their rated limit short-circuit breaking capacity.The MCCB is advantageous for its compact body, high breaking capacity (some even on flying arc), short arc-castig and superior aseismatic function.The MCCB has function of insulation with its mark (normal open contact).The product complies with IEC60947-2, GB14048.2.

  • Circuit Breaker CAM1-63L, 50 A

    Circuit Breaker CAM1-63L, 50 A

    Circuit breaker CAM1-63L, 50A Rated Voltage: 400 V;Rated Current: 50 ASize: 135 mm x 78 mm x 73.5 mm (LxWxH)Weight (g): 735Payment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAM1 series moulded case circuit breaker (named as MCCB in the following) is a new type breaker which is applied with rated insulating voltage 800V (500V for CAM1-63), rated working voltage 690V for CAM1-63) andused for infrequent exchange and startup in AC(60)Hz condition. The MCCB is of protecting functioin in overloading,short-circuit, and under voltage situation to protect circuit system and power device from damage.The MCCB can be devided into L;M;H types according to their rated limit short-circuit breaking capacity.The MCCB is advantageous for its compact body, high breaking capacity (some even on flying arc), short arc-castig and superior aseismatic function.The MCCB has function of insulation with its mark (normal open contact).The product complies with IEC60947-2, GB14048.2.

  • Circuit Breaker CAM1-63L, 63 A

    Circuit Breaker CAM1-63L, 63 A

    Circuit breaker CAM1-63L, 63A Rated Voltage: 400 V;Rated Current: 63 ASize: 135 mm x 78 mm x 73.5 mm (LxWxH)Weight (g): 735Payment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAM1 series moulded case circuit breaker (named as MCCB in the following) is a new type breaker which is applied with rated insulating voltage 800V (500V for CAM1-63), rated working voltage 690V for CAM1-63) andused for infrequent exchange and startup in AC(60)Hz condition. The MCCB is of protecting functioin in overloading,short-circuit, and under voltage situation to protect circuit system and power device from damage.The MCCB can be devided into L;M;H types according to their rated limit short-circuit breaking capacity.The MCCB is advantageous for its compact body, high breaking capacity (some even on flying arc), short arc-castig and superior aseismatic function.The MCCB has function of insulation with its mark (normal open contact).The product complies with IEC60947-2, GB14048.2.

  • Circuit Breaker CAW1-2000/1000A drawout type

    Circuit Breaker CAW1-2000/1000A drawout type

    Circuit breaker CAW1-2000/1000A drawout typeRated Voltage: 400 V, 690 V;Rated Current: 1000 ASize: 470 mm x 439 mm x 485 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/1000A drawout type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  1000A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 1000 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-2000/1000A fixed type

    Circuit Breaker CAW1-2000/1000A fixed type

    Circuit breaker CAW1-2000/1000A fixed typeRated Voltage: 400 V, 690 V;Rated Current: 1000 ASize: 435 mm x 402 mm x 349.5 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/1000A fixed type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  1000A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 1000 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-2000/1250A drawout type

    Circuit Breaker CAW1-2000/1250A drawout type

    Circuit breaker CAW1-2000/1250A drawout typeRated Voltage: 400 V, 690 V;Rated Current: 1250 ASize: 470 mm x 439 mm x 485 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/1250A drawout type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  1250A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 1250 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-2000/1250A fixed type

    Circuit Breaker CAW1-2000/1250A fixed type

    Circuit breaker CAW1-2000/1250A fixed typeRated Voltage: 400 V, 690 V;Rated Current: 1250 ASize: 435 mm x 402 mm x 349.5 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/1250A fixed type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  1250A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 1250 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-2000/1600A drawout type

    Circuit Breaker CAW1-2000/1600A drawout type

    Circuit breaker CAW1-2000/1600A drawout typeRated Voltage: 400 V, 690 V;Rated Current: 1600 ASize: 470 mm x 439 mm x 485 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/1600A drawout type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  1600A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 1600 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-2000/1600A fixed type

    Circuit Breaker CAW1-2000/1600A fixed type

    Circuit breaker CAW1-2000/1600A fixed typeRated Voltage: 400 V, 690 V;Rated Current: 1600 ASize: 435 mm x 402 mm x 349.5 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/1600A fixed type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  1600A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 1600 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-2000/2000A drawout type

    Circuit Breaker CAW1-2000/2000A drawout type

    Circuit breaker CAW1-2000/2000A drawout typeRated Voltage: 400 V, 690 V;Rated Current: 2000 ASize: 470 mm x 439 mm x 485 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/2000A drawout type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  2000A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 2000 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-2000/2000A fixed type

    Circuit Breaker CAW1-2000/2000A fixed type

    Circuit breaker CAW1-2000/2000A fixed typeRated Voltage: 400 V, 690 V;Rated Current: 2000 ASize: 435 mm x 402 mm x 349.5 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/2000A fixed type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  2000A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 2000 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-2000/630A drawout type

    Circuit Breaker CAW1-2000/630A drawout type

    Circuit breaker CAW1-2000/630A drawout typeRated Voltage: 400 V, 690 V;Rated Current: 630 ASize: 470 mm x 439 mm x 485 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/630A drawout type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  630A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 630 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-2000/630A fixed type

    Circuit Breaker CAW1-2000/630A fixed type

    Circuit breaker CAW1-2000/630A fixed typeRated Voltage: 400 V, 690 V;Rated Current: 630 ASize: 435 mm x 402 mm x 349.5 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/630A fixed type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  630A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 630 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-2000/800A drawout type

    Circuit Breaker CAW1-2000/800A drawout type

    Circuit breaker CAW1-2000/800A drawout typeRated Voltage: 400 V, 690 V;Rated Current: 800 ASize: 470 mm x 439 mm x 485 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/800A drawout type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  800A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 800 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-2000/800A fixed type

    Circuit Breaker CAW1-2000/800A fixed type

    Circuit breaker CAW1-2000/800A fixed typeRated Voltage: 400 V, 690 V;Rated Current: 800 ASize: 435 mm x 402 mm x 349.5 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-2000/800A fixed type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  800A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-2000 Frame rated current Inm (A) 2000 Number of poles 3,4 Rated current In (A) 800 Icu (Ka) 400 V 80 690 V 50 Ics= Icw (Ka) 400 V 50 690 V 40 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

  • Circuit Breaker CAW1-3200/2000A drawout type

    Circuit Breaker CAW1-3200/2000A drawout type

    Circuit breaker CAW1-3200/2000A drawout typeRated Voltage: 400 V, 690 V;Rated Current: 2000 ASize: 550 mm x 439 mm x 536 mmPayment method: T/T Prepayment 100%Delivery time: 15 days after prepaymentIncoterms: FOB WenzhouCAW1-3200/2000A drawout type series intelligent circuit breaker (hereinafter referred to as breaker) is suitable for thecircuit of AC 50/60Hz with rated voltage 400V, 690V and rated current  2000A .It ismainly used to distribute electric energy and protect circuit and power supply equipmentfrom overload, under-voltage short-circuit ,and single-phase earthing .With intelligent andselective protection functions, the breaker can improve the reliability of power supply, andavoid unnecessary power failure . The breaker is applicable for power stations, factories ,mines(for 690V) and modern high-building, especially for the distribution system of intelligentbuilding. The breaker conforms to IEC60947-2. The whole series have past CCC certification.Specification Type CAW1-3200 Frame rated current Inm (A) 3200 Number of poles 3,4 Rated current In (A) 2000 Icu (Ka) 400 V 100 690 V 65 Ics= Icw (Ka) 400 V 80 690 V 50 Rated current at N-pole In (A) 50%In, 100%In Inherent making & breaking time 23-32ms Operational performance (operations) Electric Life 500 Mechanical life Maintenance-free 2500 Maintenance 10000 Mounting mode Fixed withdrawable Arcing distance (mm) 0 Intelligent controller Standard type (M) telecommunication type (H)   Accessories Shunt releasea. Shunt release is for remote breaking of circuit breaker so as to enhance security of the operatorb. Ratings of shunt release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (70%~110%)Ue Power consumption 24VA 24VA   40W Under-voltage releasea. It is an optional accessory;b. Mainly used to protection apparatus from damage due to lowering of the operational voltage to a certain value;c. Two types of release are available: instantaneous release and time-delay release;d. For breakers appended with the release, it should be electrified continuously;e. Ratings  of under-voltage release Rated operation voltage (V) AC220V AC380V DC110V DC220V Operating voltage range (35%~110%)Us Power consumption 24VA 24VA   40W Category Under-voltage time-delay release Under-voltage instantaneous release Operation time of the release time-delay: 1s, 3s, 5s instantaneous Operational voltage of the release 35%Us~70%Us Break the breaker Break the breaker ≤35%Us Can not make the breaker Can not make the breaker ≥85%Us~110%Us Reliably make the breaker Reliably make the breaker Within ½ delay time, voltage of power supply recovers to 85% Us Can not trip the breaker Note: Error the time of time-delay is ±10%Closing electro-magneta. The magnet is for remote making of circuit breaker so as to enhance security of the operator.b. The magnet could not be electrified for a long time.c. Rating of the magnet.Auxiliary Contacta. Conventional heating current of auxiliary contact: 6A b. Auxiliary contacts: 4NO+4NC, 3NO+NC, 5NO+5NC (customization)

/