Arrancadores suaves de baja tensión serie HPS2DN

Arrancadores suaves de baja tensión serie HPS2DN

Características del producto
/
Mostrando 1 a 9 (de 9 productos)
  • Low Voltage Soft Starter 690 V, 132 kW HPS2DN series

    Low Voltage Soft Starter 690 V, 132 kW HPS2DN series

    HPS2DN145 Soft Starter: Output Power:               132 kW; Input/ Output Voltage:   690 V; Output Current:             145 A; Dimensions:                  280x218x400; Weight:                         - kg. Incoterms:         EXW Shanghai; payment:           100% T/T befor production; delivery time:     15 working days; minimum order:  USD 3000.  Purchase one sample is possible only for testing our product and only for companies.HPS2DN is a new intelligent motor soft starter which researched and developed on the basis of original HPS2S, HPS2D/DH with the most advanced digital processor which can adjust voltage and limit the electric current. The unique intelligent electronic circuit offers perfect control and protective function: Start linearly with higher speed, starting and stopping control of the pump, preset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realize automatically run with energy-saving or light load mode. The protective function of electrical machinery insulating testing , and the protection of short circuit, phase loss and the electronic. RS485 with communication interface use modbus/profibus protocol that generally realize the longrange control and monitoring. Can be extensively used in textile industry, metallurgy industry, petrochemical industry, water treatment, shipping industry, medicine, food processing industry, mine industry, and mechanical equipment industry, etc. General information Supply voltage Line to line 230V-690V (to be specified) 10% Rated Frequency 50/60Hz 4Hz (dual frequency) Control Supply 110-120V of 220-240V (to be specified) Control Inputs and Outputs 110-120V of 220-240V (to be specified) Load 3 phase, 3 wire, squirrel cage induction motor Operating temperature 0℃ to 50℃ Storage temperature -20 ℃to 70℃ Maximum starting time 30 seconds Maximum starts per hour 4 starts per hour at 400% In, Up to60 starts per hour at lower load applications Operating parameters Starter FLC Starter Full Load Current 17~950 Amp Motor FLA Motor Full Load Ampere 50%-100% of starter FLC Pump control curves 6 field selectable curves preventing over pressure during start and water hammer during stop Pulse start duration A pulse of 80% Un for adjustable time 0-1 second, to start high friction loads Initial voltage 10%-50% Un*(can be extended to 80%Un) Current limit 100%-400% of Motor FLA* (can be extended to 500%) Ramp-up time 1-30 seconds (can be extended to 90s*) Ramp-down time 1-30 seconds (can be extended to 90s*) Dual adjustments Secondary start stop characteristics for Initial voltage, current limit, acceleration time deceleration time and motor FLA. Energy saving Activated when motor is lightly loaded for extended periods Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to a maximum of 30 seconds Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tacho Starting from diesel generator Special starting characteristics become operative via an internal dip switch. (contact terminal 8,for dual adjustment) Motor protection Too many starts Determines maximum number of starts allowable during Start Period Range1-10starts in start period 1-60minutes Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO MANY STARTS is indicated Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum start time of 1-30 seconds* Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850% in during running Electronic overload (I t) Adjustable between 75%-150% of motor FLA overload curve can be selected by setting trip time at 500% in,1-10 seconds Under current Starter trips when current drops below 20%-90% ln,time delay 1-40 seconds Under voltage(**) Starter trips when mains voltage drops below 120-600V,time delay 1-10 seconds Over voltage Starter trips when mains voltage increases above 150-750V,time delay 1-10 seconds Phase loss,(under/over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency Phase sequence Starter trips when phase sequence is incorrect Long slow speed time Starter trips if operating at slow speed longer than 30 seconds Shorted SCR Prevents starting when one or more SCRs are shorted Heatsink over temperature Starter trips when heatsink temperature rises above 85 External fault Starter trips when an external contact closes for 2 seconds Motor insulation (optional) Alarm level setting 0.2-5M.Trips when motor insulation decreases below 0.2-5M setting.The thyristors must be protected against short circuit Thyristor Protection Metal Oxide Varistors(MOVs) and snubber circuits Control Analogue I/O Input of motor overheat signal Ouput of analog signals of motor current Displays LCD in 4 selectable languages and 8 LEDs Keypad 6 clearly defined keys for easy setting Aux.contact-immediate 1 C/O,8A,250V A.C,2000VA(delay 0-60 seconds) Aux.contact-end of acceleration 1 C/O,8A,250V A.C,2000VA(delay 0-120 seconds) Fault contact 1 C/O,8A,250V A.C,2000VA(selectable as trip or trip fail safe) Insulation alarm contact (optional) 1 C/O,8A,250V A.C,2000VA Communication (optional) RS 485 with Modbus/Profibus protocol for full control and supervision

  • Low Voltage Soft Starter 690 V, 160 kW HPS2DN series

    Low Voltage Soft Starter 690 V, 160 kW HPS2DN series

    HPS2DN170 Soft Starter: Output Power:               160 kW; Input/ Output Voltage:   690 V; Output Current:             170 A; Dimensions:                  382x310x446; Weight:                         - kg. Incoterms:         EXW Shanghai; payment:           100% T/T befor production; delivery time:     15 working days; minimum order:  USD 3000.  Purchase one sample is possible only for testing our product and only for companies.HPS2DN is a new intelligent motor soft starter which researched and developed on the basis of original HPS2S, HPS2D/DH with the most advanced digital processor which can adjust voltage and limit the electric current. The unique intelligent electronic circuit offers perfect control and protective function: Start linearly with higher speed, starting and stopping control of the pump, preset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realize automatically run with energy-saving or light load mode. The protective function of electrical machinery insulating testing , and the protection of short circuit, phase loss and the electronic. RS485 with communication interface use modbus/profibus protocol that generally realize the longrange control and monitoring. Can be extensively used in textile industry, metallurgy industry, petrochemical industry, water treatment, shipping industry, medicine, food processing industry, mine industry, and mechanical equipment industry, etc. General information Supply voltage Line to line 230V-690V (to be specified) 10% Rated Frequency 50/60Hz 4Hz (dual frequency) Control Supply 110-120V of 220-240V (to be specified) Control Inputs and Outputs 110-120V of 220-240V (to be specified) Load 3 phase, 3 wire, squirrel cage induction motor Operating temperature 0℃ to 50℃ Storage temperature -20 ℃to 70℃ Maximum starting time 30 seconds Maximum starts per hour 4 starts per hour at 400% In, Up to60 starts per hour at lower load applications Operating parameters Starter FLC Starter Full Load Current 17~950 Amp Motor FLA Motor Full Load Ampere 50%-100% of starter FLC Pump control curves 6 field selectable curves preventing over pressure during start and water hammer during stop Pulse start duration A pulse of 80% Un for adjustable time 0-1 second, to start high friction loads Initial voltage 10%-50% Un*(can be extended to 80%Un) Current limit 100%-400% of Motor FLA* (can be extended to 500%) Ramp-up time 1-30 seconds (can be extended to 90s*) Ramp-down time 1-30 seconds (can be extended to 90s*) Dual adjustments Secondary start stop characteristics for Initial voltage, current limit, acceleration time deceleration time and motor FLA. Energy saving Activated when motor is lightly loaded for extended periods Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to a maximum of 30 seconds Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tacho Starting from diesel generator Special starting characteristics become operative via an internal dip switch. (contact terminal 8,for dual adjustment) Motor protection Too many starts Determines maximum number of starts allowable during Start Period Range1-10starts in start period 1-60minutes Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO MANY STARTS is indicated Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum start time of 1-30 seconds* Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850% in during running Electronic overload (I t) Adjustable between 75%-150% of motor FLA overload curve can be selected by setting trip time at 500% in,1-10 seconds Under current Starter trips when current drops below 20%-90% ln,time delay 1-40 seconds Under voltage(**) Starter trips when mains voltage drops below 120-600V,time delay 1-10 seconds Over voltage Starter trips when mains voltage increases above 150-750V,time delay 1-10 seconds Phase loss,(under/over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency Phase sequence Starter trips when phase sequence is incorrect Long slow speed time Starter trips if operating at slow speed longer than 30 seconds Shorted SCR Prevents starting when one or more SCRs are shorted Heatsink over temperature Starter trips when heatsink temperature rises above 85 External fault Starter trips when an external contact closes for 2 seconds Motor insulation (optional) Alarm level setting 0.2-5M.Trips when motor insulation decreases below 0.2-5M setting.The thyristors must be protected against short circuit Thyristor Protection Metal Oxide Varistors(MOVs) and snubber circuits Control Analogue I/O Input of motor overheat signal Ouput of analog signals of motor current Displays LCD in 4 selectable languages and 8 LEDs Keypad 6 clearly defined keys for easy setting Aux.contact-immediate 1 C/O,8A,250V A.C,2000VA(delay 0-60 seconds) Aux.contact-end of acceleration 1 C/O,8A,250V A.C,2000VA(delay 0-120 seconds) Fault contact 1 C/O,8A,250V A.C,2000VA(selectable as trip or trip fail safe) Insulation alarm contact (optional) 1 C/O,8A,250V A.C,2000VA Communication (optional) RS 485 with Modbus/Profibus protocol for full control and supervision

  • Low Voltage Soft Starter 690 V, 200 kW HPS2DN series

    Low Voltage Soft Starter 690 V, 200 kW HPS2DN series

    HPS2DN210 Soft Starter: Output Power:               200 kW; Input/ Output Voltage:   690 V; Output Current:             210 A; Dimensions:                  382x310x446; Weight:                         - kg. Incoterms:         EXW Shanghai; payment:           100% T/T befor production; delivery time:     15 working days; minimum order:  USD 3000.  Purchase one sample is possible only for testing our product and only for companies.HPS2DN is a new intelligent motor soft starter which researched and developed on the basis of original HPS2S, HPS2D/DH with the most advanced digital processor which can adjust voltage and limit the electric current. The unique intelligent electronic circuit offers perfect control and protective function: Start linearly with higher speed, starting and stopping control of the pump, preset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realize automatically run with energy-saving or light load mode. The protective function of electrical machinery insulating testing , and the protection of short circuit, phase loss and the electronic. RS485 with communication interface use modbus/profibus protocol that generally realize the longrange control and monitoring. Can be extensively used in textile industry, metallurgy industry, petrochemical industry, water treatment, shipping industry, medicine, food processing industry, mine industry, and mechanical equipment industry, etc. General information Supply voltage Line to line 230V-690V (to be specified) 10% Rated Frequency 50/60Hz 4Hz (dual frequency) Control Supply 110-120V of 220-240V (to be specified) Control Inputs and Outputs 110-120V of 220-240V (to be specified) Load 3 phase, 3 wire, squirrel cage induction motor Operating temperature 0℃ to 50℃ Storage temperature -20 ℃to 70℃ Maximum starting time 30 seconds Maximum starts per hour 4 starts per hour at 400% In, Up to60 starts per hour at lower load applications Operating parameters Starter FLC Starter Full Load Current 17~950 Amp Motor FLA Motor Full Load Ampere 50%-100% of starter FLC Pump control curves 6 field selectable curves preventing over pressure during start and water hammer during stop Pulse start duration A pulse of 80% Un for adjustable time 0-1 second, to start high friction loads Initial voltage 10%-50% Un*(can be extended to 80%Un) Current limit 100%-400% of Motor FLA* (can be extended to 500%) Ramp-up time 1-30 seconds (can be extended to 90s*) Ramp-down time 1-30 seconds (can be extended to 90s*) Dual adjustments Secondary start stop characteristics for Initial voltage, current limit, acceleration time deceleration time and motor FLA. Energy saving Activated when motor is lightly loaded for extended periods Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to a maximum of 30 seconds Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tacho Starting from diesel generator Special starting characteristics become operative via an internal dip switch. (contact terminal 8,for dual adjustment) Motor protection Too many starts Determines maximum number of starts allowable during Start Period Range1-10starts in start period 1-60minutes Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO MANY STARTS is indicated Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum start time of 1-30 seconds* Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850% in during running Electronic overload (I t) Adjustable between 75%-150% of motor FLA overload curve can be selected by setting trip time at 500% in,1-10 seconds Under current Starter trips when current drops below 20%-90% ln,time delay 1-40 seconds Under voltage(**) Starter trips when mains voltage drops below 120-600V,time delay 1-10 seconds Over voltage Starter trips when mains voltage increases above 150-750V,time delay 1-10 seconds Phase loss,(under/over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency Phase sequence Starter trips when phase sequence is incorrect Long slow speed time Starter trips if operating at slow speed longer than 30 seconds Shorted SCR Prevents starting when one or more SCRs are shorted Heatsink over temperature Starter trips when heatsink temperature rises above 85 External fault Starter trips when an external contact closes for 2 seconds Motor insulation (optional) Alarm level setting 0.2-5M.Trips when motor insulation decreases below 0.2-5M setting.The thyristors must be protected against short circuit Thyristor Protection Metal Oxide Varistors(MOVs) and snubber circuits Control Analogue I/O Input of motor overheat signal Ouput of analog signals of motor current Displays LCD in 4 selectable languages and 8 LEDs Keypad 6 clearly defined keys for easy setting Aux.contact-immediate 1 C/O,8A,250V A.C,2000VA(delay 0-60 seconds) Aux.contact-end of acceleration 1 C/O,8A,250V A.C,2000VA(delay 0-120 seconds) Fault contact 1 C/O,8A,250V A.C,2000VA(selectable as trip or trip fail safe) Insulation alarm contact (optional) 1 C/O,8A,250V A.C,2000VA Communication (optional) RS 485 with Modbus/Profibus protocol for full control and supervision

  • Low Voltage Soft Starter 690 V, 257 kW HPS2DN series

    Low Voltage Soft Starter 690 V, 257 kW HPS2DN series

    HPS2DN310 Soft Starter: Output Power:               257 kW; Input/ Output Voltage:   690 V; Output Current:             310 A; Dimensions:                  540x310x600; Weight:                         - kg. Incoterms:         EXW Shanghai; payment:           100% T/T befor production; delivery time:     15 working days; minimum order:  USD 3000.  Purchase one sample is possible only for testing our product and only for companies.HPS2DN is a new intelligent motor soft starter which researched and developed on the basis of original HPS2S, HPS2D/DH with the most advanced digital processor which can adjust voltage and limit the electric current. The unique intelligent electronic circuit offers perfect control and protective function: Start linearly with higher speed, starting and stopping control of the pump, preset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realize automatically run with energy-saving or light load mode. The protective function of electrical machinery insulating testing , and the protection of short circuit, phase loss and the electronic. RS485 with communication interface use modbus/profibus protocol that generally realize the longrange control and monitoring. Can be extensively used in textile industry, metallurgy industry, petrochemical industry, water treatment, shipping industry, medicine, food processing industry, mine industry, and mechanical equipment industry, etc. General information Supply voltage Line to line 230V-690V (to be specified) 10% Rated Frequency 50/60Hz 4Hz (dual frequency) Control Supply 110-120V of 220-240V (to be specified) Control Inputs and Outputs 110-120V of 220-240V (to be specified) Load 3 phase, 3 wire, squirrel cage induction motor Operating temperature 0℃ to 50℃ Storage temperature -20 ℃to 70℃ Maximum starting time 30 seconds Maximum starts per hour 4 starts per hour at 400% In, Up to60 starts per hour at lower load applications Operating parameters Starter FLC Starter Full Load Current 17~950 Amp Motor FLA Motor Full Load Ampere 50%-100% of starter FLC Pump control curves 6 field selectable curves preventing over pressure during start and water hammer during stop Pulse start duration A pulse of 80% Un for adjustable time 0-1 second, to start high friction loads Initial voltage 10%-50% Un*(can be extended to 80%Un) Current limit 100%-400% of Motor FLA* (can be extended to 500%) Ramp-up time 1-30 seconds (can be extended to 90s*) Ramp-down time 1-30 seconds (can be extended to 90s*) Dual adjustments Secondary start stop characteristics for Initial voltage, current limit, acceleration time deceleration time and motor FLA. Energy saving Activated when motor is lightly loaded for extended periods Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to a maximum of 30 seconds Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tacho Starting from diesel generator Special starting characteristics become operative via an internal dip switch. (contact terminal 8,for dual adjustment) Motor protection Too many starts Determines maximum number of starts allowable during Start Period Range1-10starts in start period 1-60minutes Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO MANY STARTS is indicated Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum start time of 1-30 seconds* Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850% in during running Electronic overload (I t) Adjustable between 75%-150% of motor FLA overload curve can be selected by setting trip time at 500% in,1-10 seconds Under current Starter trips when current drops below 20%-90% ln,time delay 1-40 seconds Under voltage(**) Starter trips when mains voltage drops below 120-600V,time delay 1-10 seconds Over voltage Starter trips when mains voltage increases above 150-750V,time delay 1-10 seconds Phase loss,(under/over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency Phase sequence Starter trips when phase sequence is incorrect Long slow speed time Starter trips if operating at slow speed longer than 30 seconds Shorted SCR Prevents starting when one or more SCRs are shorted Heatsink over temperature Starter trips when heatsink temperature rises above 85 External fault Starter trips when an external contact closes for 2 seconds Motor insulation (optional) Alarm level setting 0.2-5M.Trips when motor insulation decreases below 0.2-5M setting.The thyristors must be protected against short circuit Thyristor Protection Metal Oxide Varistors(MOVs) and snubber circuits Control Analogue I/O Input of motor overheat signal Ouput of analog signals of motor current Displays LCD in 4 selectable languages and 8 LEDs Keypad 6 clearly defined keys for easy setting Aux.contact-immediate 1 C/O,8A,250V A.C,2000VA(delay 0-60 seconds) Aux.contact-end of acceleration 1 C/O,8A,250V A.C,2000VA(delay 0-120 seconds) Fault contact 1 C/O,8A,250V A.C,2000VA(selectable as trip or trip fail safe) Insulation alarm contact (optional) 1 C/O,8A,250V A.C,2000VA Communication (optional) RS 485 with Modbus/Profibus protocol for full control and supervision

  • Low Voltage Soft Starter 690 V, 355 kW HPS2DN series

    Low Voltage Soft Starter 690 V, 355 kW HPS2DN series

    HPS2DN390 Soft Starter: Output Power:               355 kW; Input/ Output Voltage:   690 V; Output Current:            390 A; Dimensions:                  540x310x600; Weight:                         - kg. Incoterms:         EXW Shanghai; payment:           100% T/T befor production; delivery time:     15 working days; minimum order:  USD 3000.  Purchase one sample is possible only for testing our product and only for companies.HPS2DN is a new intelligent motor soft starter which researched and developed on the basis of original HPS2S, HPS2D/DH with the most advanced digital processor which can adjust voltage and limit the electric current. The unique intelligent electronic circuit offers perfect control and protective function: Start linearly with higher speed, starting and stopping control of the pump, preset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realize automatically run with energy-saving or light load mode. The protective function of electrical machinery insulating testing , and the protection of short circuit, phase loss and the electronic. RS485 with communication interface use modbus/profibus protocol that generally realize the longrange control and monitoring. Can be extensively used in textile industry, metallurgy industry, petrochemical industry, water treatment, shipping industry, medicine, food processing industry, mine industry, and mechanical equipment industry, etc. General information Supply voltage Line to line 230V-690V (to be specified) 10% Rated Frequency 50/60Hz 4Hz (dual frequency) Control Supply 110-120V of 220-240V (to be specified) Control Inputs and Outputs 110-120V of 220-240V (to be specified) Load 3 phase, 3 wire, squirrel cage induction motor Operating temperature 0℃ to 50℃ Storage temperature -20 ℃to 70℃ Maximum starting time 30 seconds Maximum starts per hour 4 starts per hour at 400% In, Up to60 starts per hour at lower load applications Operating parameters Starter FLC Starter Full Load Current 17~950 Amp Motor FLA Motor Full Load Ampere 50%-100% of starter FLC Pump control curves 6 field selectable curves preventing over pressure during start and water hammer during stop Pulse start duration A pulse of 80% Un for adjustable time 0-1 second, to start high friction loads Initial voltage 10%-50% Un*(can be extended to 80%Un) Current limit 100%-400% of Motor FLA* (can be extended to 500%) Ramp-up time 1-30 seconds (can be extended to 90s*) Ramp-down time 1-30 seconds (can be extended to 90s*) Dual adjustments Secondary start stop characteristics for Initial voltage, current limit, acceleration time deceleration time and motor FLA. Energy saving Activated when motor is lightly loaded for extended periods Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to a maximum of 30 seconds Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tacho Starting from diesel generator Special starting characteristics become operative via an internal dip switch. (contact terminal 8,for dual adjustment) Motor protection Too many starts Determines maximum number of starts allowable during Start Period Range1-10starts in start period 1-60minutes Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO MANY STARTS is indicated Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum start time of 1-30 seconds* Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850% in during running Electronic overload (I t) Adjustable between 75%-150% of motor FLA overload curve can be selected by setting trip time at 500% in,1-10 seconds Under current Starter trips when current drops below 20%-90% ln,time delay 1-40 seconds Under voltage(**) Starter trips when mains voltage drops below 120-600V,time delay 1-10 seconds Over voltage Starter trips when mains voltage increases above 150-750V,time delay 1-10 seconds Phase loss,(under/over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency Phase sequence Starter trips when phase sequence is incorrect Long slow speed time Starter trips if operating at slow speed longer than 30 seconds Shorted SCR Prevents starting when one or more SCRs are shorted Heatsink over temperature Starter trips when heatsink temperature rises above 85 External fault Starter trips when an external contact closes for 2 seconds Motor insulation (optional) Alarm level setting 0.2-5M.Trips when motor insulation decreases below 0.2-5M setting.The thyristors must be protected against short circuit Thyristor Protection Metal Oxide Varistors(MOVs) and snubber circuits Control Analogue I/O Input of motor overheat signal Ouput of analog signals of motor current Displays LCD in 4 selectable languages and 8 LEDs Keypad 6 clearly defined keys for easy setting Aux.contact-immediate 1 C/O,8A,250V A.C,2000VA(delay 0-60 seconds) Aux.contact-end of acceleration 1 C/O,8A,250V A.C,2000VA(delay 0-120 seconds) Fault contact 1 C/O,8A,250V A.C,2000VA(selectable as trip or trip fail safe) Insulation alarm contact (optional) 1 C/O,8A,250V A.C,2000VA Communication (optional) RS 485 with Modbus/Profibus protocol for full control and supervision

  • Low Voltage Soft Starter 690 V, 450 kW HPS2DN series

    Low Voltage Soft Starter 690 V, 450 kW HPS2DN series

    HPS2DN460 Soft Starter: Output Power:               450 kW; Input/ Output Voltage:   690 V; Output Current:            460 A; Dimensions:                  540x310x600; Weight:                         - kg. Incoterms:         EXW Shanghai; payment:           100% T/T befor production; delivery time:     15 working days; minimum order:  USD 3000.  Purchase one sample is possible only for testing our product and only for companies.HPS2DN is a new intelligent motor soft starter which researched and developed on the basis of original HPS2S, HPS2D/DH with the most advanced digital processor which can adjust voltage and limit the electric current. The unique intelligent electronic circuit offers perfect control and protective function: Start linearly with higher speed, starting and stopping control of the pump, preset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realize automatically run with energy-saving or light load mode. The protective function of electrical machinery insulating testing , and the protection of short circuit, phase loss and the electronic. RS485 with communication interface use modbus/profibus protocol that generally realize the longrange control and monitoring. Can be extensively used in textile industry, metallurgy industry, petrochemical industry, water treatment, shipping industry, medicine, food processing industry, mine industry, and mechanical equipment industry, etc. General information Supply voltage Line to line 230V-690V (to be specified) 10% Rated Frequency 50/60Hz 4Hz (dual frequency) Control Supply 110-120V of 220-240V (to be specified) Control Inputs and Outputs 110-120V of 220-240V (to be specified) Load 3 phase, 3 wire, squirrel cage induction motor Operating temperature 0℃ to 50℃ Storage temperature -20 ℃to 70℃ Maximum starting time 30 seconds Maximum starts per hour 4 starts per hour at 400% In, Up to60 starts per hour at lower load applications Operating parameters Starter FLC Starter Full Load Current 17~950 Amp Motor FLA Motor Full Load Ampere 50%-100% of starter FLC Pump control curves 6 field selectable curves preventing over pressure during start and water hammer during stop Pulse start duration A pulse of 80% Un for adjustable time 0-1 second, to start high friction loads Initial voltage 10%-50% Un*(can be extended to 80%Un) Current limit 100%-400% of Motor FLA* (can be extended to 500%) Ramp-up time 1-30 seconds (can be extended to 90s*) Ramp-down time 1-30 seconds (can be extended to 90s*) Dual adjustments Secondary start stop characteristics for Initial voltage, current limit, acceleration time deceleration time and motor FLA. Energy saving Activated when motor is lightly loaded for extended periods Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to a maximum of 30 seconds Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tacho Starting from diesel generator Special starting characteristics become operative via an internal dip switch. (contact terminal 8,for dual adjustment) Motor protection Too many starts Determines maximum number of starts allowable during Start Period Range1-10starts in start period 1-60minutes Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO MANY STARTS is indicated Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum start time of 1-30 seconds* Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850% in during running Electronic overload (I t) Adjustable between 75%-150% of motor FLA overload curve can be selected by setting trip time at 500% in,1-10 seconds Under current Starter trips when current drops below 20%-90% ln,time delay 1-40 seconds Under voltage(**) Starter trips when mains voltage drops below 120-600V,time delay 1-10 seconds Over voltage Starter trips when mains voltage increases above 150-750V,time delay 1-10 seconds Phase loss,(under/over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency Phase sequence Starter trips when phase sequence is incorrect Long slow speed time Starter trips if operating at slow speed longer than 30 seconds Shorted SCR Prevents starting when one or more SCRs are shorted Heatsink over temperature Starter trips when heatsink temperature rises above 85 External fault Starter trips when an external contact closes for 2 seconds Motor insulation (optional) Alarm level setting 0.2-5M.Trips when motor insulation decreases below 0.2-5M setting.The thyristors must be protected against short circuit Thyristor Protection Metal Oxide Varistors(MOVs) and snubber circuits Control Analogue I/O Input of motor overheat signal Ouput of analog signals of motor current Displays LCD in 4 selectable languages and 8 LEDs Keypad 6 clearly defined keys for easy setting Aux.contact-immediate 1 C/O,8A,250V A.C,2000VA(delay 0-60 seconds) Aux.contact-end of acceleration 1 C/O,8A,250V A.C,2000VA(delay 0-120 seconds) Fault contact 1 C/O,8A,250V A.C,2000VA(selectable as trip or trip fail safe) Insulation alarm contact (optional) 1 C/O,8A,250V A.C,2000VA Communication (optional) RS 485 with Modbus/Profibus protocol for full control and supervision

  • Low Voltage Soft Starter 690 V, 55 kW HPS2DN series

    Low Voltage Soft Starter 690 V, 55 kW HPS2DN series

    HPS2DN58 Soft Starter: Output Power:               55 kW; Input/ Output Voltage:   690 V; Output Current:             58 A; Dimensions:                  280x218x400; Weight:                         - kg. Incoterms:         EXW Shanghai; payment:           100% T/T befor production; delivery time:     15 working days; minimum order:  USD 3000.  Purchase one sample is possible only for testing our product and only for companies.HPS2DN is a new intelligent motor soft starter which researched and developed on the basis of original HPS2S, HPS2D/DH with the most advanced digital processor which can adjust voltage and limit the electric current. The unique intelligent electronic circuit offers perfect control and protective function: Start linearly with higher speed, starting and stopping control of the pump, preset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realize automatically run with energy-saving or light load mode. The protective function of electrical machinery insulating testing , and the protection of short circuit, phase loss and the electronic. RS485 with communication interface use modbus/profibus protocol that generally realize the longrange control and monitoring. Can be extensively used in textile industry, metallurgy industry, petrochemical industry, water treatment, shipping industry, medicine, food processing industry, mine industry, and mechanical equipment industry, etc. General information Supply voltage Line to line 230V-690V (to be specified) 10% Rated Frequency 50/60Hz 4Hz (dual frequency) Control Supply 110-120V of 220-240V (to be specified) Control Inputs and Outputs 110-120V of 220-240V (to be specified) Load 3 phase, 3 wire, squirrel cage induction motor Operating temperature 0℃ to 50℃ Storage temperature -20 ℃to 70℃ Maximum starting time 30 seconds Maximum starts per hour 4 starts per hour at 400% In, Up to60 starts per hour at lower load applications Operating parameters Starter FLC Starter Full Load Current 17~950 Amp Motor FLA Motor Full Load Ampere 50%-100% of starter FLC Pump control curves 6 field selectable curves preventing over pressure during start and water hammer during stop Pulse start duration A pulse of 80% Un for adjustable time 0-1 second, to start high friction loads Initial voltage 10%-50% Un*(can be extended to 80%Un) Current limit 100%-400% of Motor FLA* (can be extended to 500%) Ramp-up time 1-30 seconds (can be extended to 90s*) Ramp-down time 1-30 seconds (can be extended to 90s*) Dual adjustments Secondary start stop characteristics for Initial voltage, current limit, acceleration time deceleration time and motor FLA. Energy saving Activated when motor is lightly loaded for extended periods Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to a maximum of 30 seconds Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tacho Starting from diesel generator Special starting characteristics become operative via an internal dip switch. (contact terminal 8,for dual adjustment) Motor protection Too many starts Determines maximum number of starts allowable during Start Period Range1-10starts in start period 1-60minutes Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO MANY STARTS is indicated Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum start time of 1-30 seconds* Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850% in during running Electronic overload (I t) Adjustable between 75%-150% of motor FLA overload curve can be selected by setting trip time at 500% in,1-10 seconds Under current Starter trips when current drops below 20%-90% ln,time delay 1-40 seconds Under voltage(**) Starter trips when mains voltage drops below 120-600V,time delay 1-10 seconds Over voltage Starter trips when mains voltage increases above 150-750V,time delay 1-10 seconds Phase loss,(under/over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency Phase sequence Starter trips when phase sequence is incorrect Long slow speed time Starter trips if operating at slow speed longer than 30 seconds Shorted SCR Prevents starting when one or more SCRs are shorted Heatsink over temperature Starter trips when heatsink temperature rises above 85 External fault Starter trips when an external contact closes for 2 seconds Motor insulation (optional) Alarm level setting 0.2-5M.Trips when motor insulation decreases below 0.2-5M setting.The thyristors must be protected against short circuit Thyristor Protection Metal Oxide Varistors(MOVs) and snubber circuits Control Analogue I/O Input of motor overheat signal Ouput of analog signals of motor current Displays LCD in 4 selectable languages and 8 LEDs Keypad 6 clearly defined keys for easy setting Aux.contact-immediate 1 C/O,8A,250V A.C,2000VA(delay 0-60 seconds) Aux.contact-end of acceleration 1 C/O,8A,250V A.C,2000VA(delay 0-120 seconds) Fault contact 1 C/O,8A,250V A.C,2000VA(selectable as trip or trip fail safe) Insulation alarm contact (optional) 1 C/O,8A,250V A.C,2000VA Communication (optional) RS 485 with Modbus/Profibus protocol for full control and supervision

  • Low Voltage Soft Starter 690 V, 75 kW HPS2DN series

    Low Voltage Soft Starter 690 V, 75 kW HPS2DN series

    HPS2DN85 Soft Starter: Output Power:               75 kW; Input/ Output Voltage:   690 V; Output Current:             85 A; Dimensions:                  280x218x400; Weight:                         - kg. Incoterms:         EXW Shanghai; payment:           100% T/T befor production; delivery time:     15 working days; minimum order:  USD 3000.  Purchase one sample is possible only for testing our product and only for companies.HPS2DN is a new intelligent motor soft starter which researched and developed on the basis of original HPS2S, HPS2D/DH with the most advanced digital processor which can adjust voltage and limit the electric current. The unique intelligent electronic circuit offers perfect control and protective function: Start linearly with higher speed, starting and stopping control of the pump, preset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realize automatically run with energy-saving or light load mode. The protective function of electrical machinery insulating testing , and the protection of short circuit, phase loss and the electronic. RS485 with communication interface use modbus/profibus protocol that generally realize the longrange control and monitoring. Can be extensively used in textile industry, metallurgy industry, petrochemical industry, water treatment, shipping industry, medicine, food processing industry, mine industry, and mechanical equipment industry, etc. General information Supply voltage Line to line 230V-690V (to be specified) 10% Rated Frequency 50/60Hz 4Hz (dual frequency) Control Supply 110-120V of 220-240V (to be specified) Control Inputs and Outputs 110-120V of 220-240V (to be specified) Load 3 phase, 3 wire, squirrel cage induction motor Operating temperature 0℃ to 50℃ Storage temperature -20 ℃to 70℃ Maximum starting time 30 seconds Maximum starts per hour 4 starts per hour at 400% In, Up to60 starts per hour at lower load applications Operating parameters Starter FLC Starter Full Load Current 17~950 Amp Motor FLA Motor Full Load Ampere 50%-100% of starter FLC Pump control curves 6 field selectable curves preventing over pressure during start and water hammer during stop Pulse start duration A pulse of 80% Un for adjustable time 0-1 second, to start high friction loads Initial voltage 10%-50% Un*(can be extended to 80%Un) Current limit 100%-400% of Motor FLA* (can be extended to 500%) Ramp-up time 1-30 seconds (can be extended to 90s*) Ramp-down time 1-30 seconds (can be extended to 90s*) Dual adjustments Secondary start stop characteristics for Initial voltage, current limit, acceleration time deceleration time and motor FLA. Energy saving Activated when motor is lightly loaded for extended periods Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to a maximum of 30 seconds Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tacho Starting from diesel generator Special starting characteristics become operative via an internal dip switch. (contact terminal 8,for dual adjustment) Motor protection Too many starts Determines maximum number of starts allowable during Start Period Range1-10starts in start period 1-60minutes Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO MANY STARTS is indicated Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum start time of 1-30 seconds* Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850% in during running Electronic overload (I t) Adjustable between 75%-150% of motor FLA overload curve can be selected by setting trip time at 500% in,1-10 seconds Under current Starter trips when current drops below 20%-90% ln,time delay 1-40 seconds Under voltage(**) Starter trips when mains voltage drops below 120-600V,time delay 1-10 seconds Over voltage Starter trips when mains voltage increases above 150-750V,time delay 1-10 seconds Phase loss,(under/over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency Phase sequence Starter trips when phase sequence is incorrect Long slow speed time Starter trips if operating at slow speed longer than 30 seconds Shorted SCR Prevents starting when one or more SCRs are shorted Heatsink over temperature Starter trips when heatsink temperature rises above 85 External fault Starter trips when an external contact closes for 2 seconds Motor insulation (optional) Alarm level setting 0.2-5M.Trips when motor insulation decreases below 0.2-5M setting.The thyristors must be protected against short circuit Thyristor Protection Metal Oxide Varistors(MOVs) and snubber circuits Control Analogue I/O Input of motor overheat signal Ouput of analog signals of motor current Displays LCD in 4 selectable languages and 8 LEDs Keypad 6 clearly defined keys for easy setting Aux.contact-immediate 1 C/O,8A,250V A.C,2000VA(delay 0-60 seconds) Aux.contact-end of acceleration 1 C/O,8A,250V A.C,2000VA(delay 0-120 seconds) Fault contact 1 C/O,8A,250V A.C,2000VA(selectable as trip or trip fail safe) Insulation alarm contact (optional) 1 C/O,8A,250V A.C,2000VA Communication (optional) RS 485 with Modbus/Profibus protocol for full control and supervision

  • Low Voltage Soft Starter 690 V, 90 kW HPS2DN series

    Low Voltage Soft Starter 690 V, 90 kW HPS2DN series

    HPS2DN105 Soft Starter: Output Power:               90 kW; Input/ Output Voltage:   690 V; Output Current:             105 A; Dimensions:                  280x218x400; Weight:                         - kg. Incoterms:         EXW Shanghai; payment:           100% T/T befor production; delivery time:     15 working days; minimum order:  USD 3000.  Purchase one sample is possible only for testing our product and only for companies.HPS2DN is a new intelligent motor soft starter which researched and developed on the basis of original HPS2S, HPS2D/DH with the most advanced digital processor which can adjust voltage and limit the electric current. The unique intelligent electronic circuit offers perfect control and protective function: Start linearly with higher speed, starting and stopping control of the pump, preset run at a low speed(rotating and overturning adjustment in short time of electro-controllingtype). Presetable dual start-stop parameter switch freely, can monitor the load state and realize automatically run with energy-saving or light load mode. The protective function of electrical machinery insulating testing , and the protection of short circuit, phase loss and the electronic. RS485 with communication interface use modbus/profibus protocol that generally realize the longrange control and monitoring. Can be extensively used in textile industry, metallurgy industry, petrochemical industry, water treatment, shipping industry, medicine, food processing industry, mine industry, and mechanical equipment industry, etc. General information Supply voltage Line to line 230V-690V (to be specified) 10% Rated Frequency 50/60Hz 4Hz (dual frequency) Control Supply 110-120V of 220-240V (to be specified) Control Inputs and Outputs 110-120V of 220-240V (to be specified) Load 3 phase, 3 wire, squirrel cage induction motor Operating temperature 0℃ to 50℃ Storage temperature -20 ℃to 70℃ Maximum starting time 30 seconds Maximum starts per hour 4 starts per hour at 400% In, Up to60 starts per hour at lower load applications Operating parameters Starter FLC Starter Full Load Current 17~950 Amp Motor FLA Motor Full Load Ampere 50%-100% of starter FLC Pump control curves 6 field selectable curves preventing over pressure during start and water hammer during stop Pulse start duration A pulse of 80% Un for adjustable time 0-1 second, to start high friction loads Initial voltage 10%-50% Un*(can be extended to 80%Un) Current limit 100%-400% of Motor FLA* (can be extended to 500%) Ramp-up time 1-30 seconds (can be extended to 90s*) Ramp-down time 1-30 seconds (can be extended to 90s*) Dual adjustments Secondary start stop characteristics for Initial voltage, current limit, acceleration time deceleration time and motor FLA. Energy saving Activated when motor is lightly loaded for extended periods Slow speed torque Maximum torque produced while motor is operating at 1/6 of nominal speed to a maximum of 30 seconds Tacho and linear acceleration 12 selectable curves-defines gain control to improve the tacho Starting from diesel generator Special starting characteristics become operative via an internal dip switch. (contact terminal 8,for dual adjustment) Motor protection Too many starts Determines maximum number of starts allowable during Start Period Range1-10starts in start period 1-60minutes Start inhibit Prevents starting for a variable period of 1-60 minutes after TOO MANY STARTS is indicated Long start time (stall protection) Starter trips if the full motor speed is not reached within the maximum start time of 1-30 seconds* Electronic fuse (shear pin) Trips starter in 1 cycle at 850% in during starting and 200%-850% in during running Electronic overload (I t) Adjustable between 75%-150% of motor FLA overload curve can be selected by setting trip time at 500% in,1-10 seconds Under current Starter trips when current drops below 20%-90% ln,time delay 1-40 seconds Under voltage(**) Starter trips when mains voltage drops below 120-600V,time delay 1-10 seconds Over voltage Starter trips when mains voltage increases above 150-750V,time delay 1-10 seconds Phase loss,(under/over frequency**) Starter trips when 1 or 2 phases fail and when frequency is 4Hz of nominal frequency Phase sequence Starter trips when phase sequence is incorrect Long slow speed time Starter trips if operating at slow speed longer than 30 seconds Shorted SCR Prevents starting when one or more SCRs are shorted Heatsink over temperature Starter trips when heatsink temperature rises above 85 External fault Starter trips when an external contact closes for 2 seconds Motor insulation (optional) Alarm level setting 0.2-5M.Trips when motor insulation decreases below 0.2-5M setting.The thyristors must be protected against short circuit Thyristor Protection Metal Oxide Varistors(MOVs) and snubber circuits Control Analogue I/O Input of motor overheat signal Ouput of analog signals of motor current Displays LCD in 4 selectable languages and 8 LEDs Keypad 6 clearly defined keys for easy setting Aux.contact-immediate 1 C/O,8A,250V A.C,2000VA(delay 0-60 seconds) Aux.contact-end of acceleration 1 C/O,8A,250V A.C,2000VA(delay 0-120 seconds) Fault contact 1 C/O,8A,250V A.C,2000VA(selectable as trip or trip fail safe) Insulation alarm contact (optional) 1 C/O,8A,250V A.C,2000VA Communication (optional) RS 485 with Modbus/Profibus protocol for full control and supervision

/