Manufacturers
  • Advanced Electric Systems LLC
Cast resin transformer SC(B)10-6

Cast resin transformer SC(B)10-6

/
Displaying 1 to 12 (of 12 products)
  • Cast resin transformer SC10-200/6, 200 kVA, 6 kV

    Cast resin transformer SC10-200/6, 200 kVA, 6 kV

     Cast resin dry transformer: Capacity:                            200 kVA;HV:                                    6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days. The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)2006291.02525412301210*870*1165

  • Cast resin transformer SC10-250/6, 250 kVA, 6 kV

    Cast resin transformer SC10-250/6, 250 kVA, 6 kV

        Cast resin dry transformer: Capacity:                            250 kVA;HV:                                     6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days.The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)2507201.02755413601210*870*1245

  • Cast resin transformer SCB10-1000/6, 1000 kVA, 6 kV

    Cast resin transformer SCB10-1000/6, 1000 kVA, 6 kV

         Cast resin dry transformer: Capacity:                            1000 kVA;HV:                                    6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days. The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)100017650.68130429501640*1020*1465

  • Cast resin transformer SCB10-1250/6, 1250 kVA, 6 kV

    Cast resin transformer SCB10-1250/6, 1250 kVA, 6 kV

           Cast resin dry transformer: Capacity:                            1250 kVA;HV:                                     6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days.  The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)125020850.49690434201700*1020*1585

  • Cast resin transformer SCB10-1600/6, 1600 kVA, 6 kV

    Cast resin transformer SCB10-1600/6, 1600 kVA, 6 kV

             Cast resin dry transformer: Capacity:                            1600 kVA;HV:                                     6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days. The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)160024400.411730441701820*1070*1655

  • Cast resin transformer SCB10-2000/6, 2000 kVA, 6 kV

    Cast resin transformer SCB10-2000/6, 2000 kVA, 6 kV

               Cast resin dry transformer: Capacity:                            2000 kVA;HV:                                     6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days.The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)200033200.414450449501910*1070*1785

  • Cast resin transformer SCB10-2500/6, 2500 kVA, 6 kV

    Cast resin transformer SCB10-2500/6, 2500 kVA, 6 kV

     Cast resin dry transformer: Capacity:                            2500 kVA;HV:                                     6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days. The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)250040000.417170467502140*870*1990

  • Cast resin transformer SCB10-315/6, 315 kVA, 6 kV

    Cast resin transformer SCB10-315/6, 315 kVA, 6 kV

     Cast resin dry transformer: Capacity:                            315 kVA;HV:                                     6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days.  The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)3158800.83470416801300*870*1170

  • Cast resin transformer SCB10-400/6, 400 kVA, 6 kV

    Cast resin transformer SCB10-400/6, 400 kVA, 6 kV

      Cast resin dry transformer: Capacity:                            400 kVA;HV:                                     6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days.  The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)4009700.83990417801340*870*1255

  • Cast resin transformer SCB10-500/6, 500 kVA, 6 kV

    Cast resin transformer SCB10-500/6, 500 kVA, 6 kV

       Cast resin dry transformer: Capacity:                            500 kVA;HV:                                     6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days. The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)50011600.84880418301360*1020*1415

  • Cast resin transformer SCB10-630/6, 630 kVA, 6 kV

    Cast resin transformer SCB10-630/6, 630 kVA, 6 kV

        Cast resin dry transformer: Capacity:                            630 kVA;HV:                                     6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days. The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)63012500.85875421301420*1020*1430

  • Cast resin transformer SCB10-800/6, 800 kVA, 6 kV

    Cast resin transformer SCB10-800/6, 800 kVA, 6 kV

        Cast resin dry transformer: Capacity:                            800 kVA;HV:                                     6 kV;LV:                                     400 V;Standards supported:           IEC, GOST, CSA.Incoterms:                    FOB Shanghai;Payment:                       50% T/T befor production;                                       50% T/T befor shipment;Manufacturing time:    30 days. The main specification of the transformer:1. Transformer core is made of sheet steel cold rolled steel, special technology.2. All nesessary constructions of transformer  provides for fast and easy installation manualy.3. Transformers can operate at 100% humidity and do not require pre-drying prior to commissioning.4. The transformer creates minimum acoustic noise.5. The transformer has a high reliability and high performance.6. Easy to dismantle and disposal, virtually no harmful and heavy metals (lead). Line of dry transformers 6 kV / 0.4 kV, intended for use in substations to supply industrial and civilian targets.The following table lists the specifications of dry transformer cast resin type SC (B) 10Voltage(KV): HV:6 LV:0.4Tapping: ±5% or ±2*2.5%Vector: Yyn0 or Dyn11Capacity, kVAUn-load loss(W)Un-loadcurrent(%)Load loss(120 °C (W )Impemdance(%)Weight (kg)Dimension (L*W*H mm)80015200.66955424501500*1020*1430

/