UNT-HVSS softstarter 6 kV

UNT-HVSS softstarter 6 kV

Product Attributes
/
Displaying 1 to 20 (of 34 products)
  • UNT-HVSS-BZ-D-1050

    UNT-HVSS-BZ-D-1050

     Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       9500 kW;Rate voltage:                        6 kV;Rate current:                       1050 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms: FOB Xingang Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-1110

    UNT-HVSS-BZ-D-1110

     Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       10000 kW;Rate voltage:                        6 kV;Rate current:                       1110 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms: FOB Xingang Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-115

    UNT-HVSS-BZ-D-115

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       900 kW;Rate voltage:                        6 kV;Rate current:                        115 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-1220

    UNT-HVSS-BZ-D-1220

     Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       11000 kW;Rate voltage:                        6 kV;Rate current:                       1220 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms: FOB XingangFor soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-1330

    UNT-HVSS-BZ-D-1330

     Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       12000 kW;Rate voltage:                        6 kV;Rate current:                       1330 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms: FOB XingangFor soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-140

    UNT-HVSS-BZ-D-140

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       1200 kW;Rate voltage:                        6 kV;Rate current:                        140 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-175

    UNT-HVSS-BZ-D-175

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       1500 kW;Rate voltage:                        6 kV;Rate current:                        175 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-20

    UNT-HVSS-BZ-D-20

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       150 kW;Rate voltage:                        6 kV;Rate current:                        20 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-210

    UNT-HVSS-BZ-D-210

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       1800 kW;Rate voltage:                        6 kV;Rate current:                        210 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-230

    UNT-HVSS-BZ-D-230

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       2000 kW;Rate voltage:                        6 kV;Rate current:                        230 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-25

    UNT-HVSS-BZ-D-25

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       200 kW;Rate voltage:                        6 kV;Rate current:                        25 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-250

    UNT-HVSS-BZ-D-250

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       2200 kW;Rate voltage:                        6 kV;Rate current:                        250 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-270

    UNT-HVSS-BZ-D-270

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       2400 kW;Rate voltage:                        6 kV;Rate current:                        270 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-280

    UNT-HVSS-BZ-D-280

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       2500 kW;Rate voltage:                        6 kV;Rate current:                        280 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-315

    UNT-HVSS-BZ-D-315

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       2800 kW;Rate voltage:                        6 kV;Rate current:                        315 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-335

    UNT-HVSS-BZ-D-335

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       3000 kW;Rate voltage:                        6 kV;Rate current:                        335 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-365

    UNT-HVSS-BZ-D-365

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       3300 kW;Rate voltage:                        6 kV;Rate current:                        365 A;Dimensions (two cabinets): 1000x1500x2300mm;                                             1200x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-40

    UNT-HVSS-BZ-D-40

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       300 kW;Rate voltage:                        6 kV;Rate current:                        40 A;Dimensions:              1000x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-400

    UNT-HVSS-BZ-D-400

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       3600 kW;Rate voltage:                        6 kV;Rate current:                        400 A;Dimensions (two cabinets): 1000x1500x2300mm;                                             1200x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

  • UNT-HVSS-BZ-D-445

    UNT-HVSS-BZ-D-445

    For this product provided full technical support. For any questions ask to refer>> Medium Voltage Softstarter for one AC motor: Rate power of AC motor:       4000 kW;Rate voltage:                        6 kV;Rate current:                        445 A;Dimensions (two cabinets): 1000x1500x2300mm;                                             1200x1500x2300mm;Weight:                               - kg.Incoterms:        FOB Xingang;payment:          50% T/T befor production;                         50% T/T befor shipment;Delivery time:    45 days.For soft starter ordering please fill your requirements in questionnaire >>Medium voltage soft starter instruction manual >> Specification● The embedded high reliability & real time motor protection function can monitor the motor’s working conditions when it starts or under the normal operation.  ● Applying the touch screen interface, the operation is much more convenient and comfortable, there is component structure inside the equipment and modular installation is available, the equipment has multiple overvoltage absorption and protection function. The equipment can decrease the harmful impact on grid when motor gets start by limiting and clipping of instantaneous dv/dt, lightning impulse voltage, switching overvoltage and transient transition progress.  ● The device has the mode of multiple optional soft start and soft stop, applies to no-load, full load, and 150% overload starting. Jumping mode can realize the smooth start under bigger over-load, which can save the investment cost and prolong the lifetime of the motors and have a good performance on energy saving. The equipment is the best substitute for imported ones.  Protection & Monitoring ● Over voltage protection, under voltage protection ● Active power/Reactive power Testing ● Overload protection, under voltage protection ● Power factor monitoring ● Phase shortage protection, Phase sequence protection ● Motor temperature protection, Over hot Protection ●Short Circuit Protection, Motor Shaft Lock Protection ● Phase Current Unbalance Protection ● Frequency Protection, Ground Connection/Leakage Protection ● Starting time Leakage limitation.Specification of UNT-HVSS softstarter series: Working conditions Load type Three-phase HV/MV asynchronous squirrel-cage motor, synchronous motor Voltage range 6 kV; 10 kV Rate frequency 50Hz ± 2Hz General power range 6 kV        150 kW-12000 kW 10 kV         200 kW-20000 kW Control power 220VAC, supplied by cabinet PT or on spot small bus Cooling method natural air cooling Environment requirements Ambient temperature: -15℃-50℃ Relative humidity: 5%-95% Altitude: up to 2000 m Locations without metal chips, conductive dusts, corrosive Setting parameters Startup mode Voltage ramp start Constant current start Kick-up start Startup period (1-120) s, adjustable Startup current (1.0 -5.0) Ie, adjustable Initial voltage (30-100) % Ue, adjustable Kick-up impulse period (1-5) s, adjustable Shutdown mode Direct shutdown/soft shutdown Soft shutdown period (1-120) s, adjustable Protection functions Underload protection Setting range: (1-99) % Irate Actuation time: (1-250) s Overload protection Setting range: (100-400) % Ie (effective when bypass is running) Actuation time: (1-250) s Undervoltage protection Setting range: (1-99) % Ue Actuation time: (1-250) s Overvoltage protection Setting range: (100-180) % Ue Actuation time: (1-250) s Open-phase protection Actuation time: (1-250) s Phase-sequence protection Actuation time: 0 s Startup overfrequency protectionrts Setting range: startup or shutdown (1-99) times or non protection per hour Actuation time: 0 s Three-phase current unbalanced protection Setting range: (1-100) % Actuation time: (1-250) s  Bypass abnormality protection after startup Actuation time: 2 s Thyristor fault protection Actuation time: 0 s Locked rotor protection Setting range: (400-800) % Ie Actuation time: 0 s Communication interface Communication interface RS-485 Communication protocol (optional) Modbus RTU, Profibus DP Operation interface User-friendly man-machine interface 7-inch colored touch screen display Display content in touch screen Display whether system working voltage value and curve, working current value and curve, communication and working status are normal Memory function Historic fault record Record most recent five fault messages, including fault type and system working state when fault occurs

/